Ducted Air Conditioning Regas

Re-gas of an Air conditioner Brisbane Area : Ducted Air Conditioning System Re-gas.

When re-gassing an air conditioning unit the correct procedure should prevent the system from leaking again. All split systems have 2 main connection points which are joined using a flaring tool when the air conditioner is installed. The pipe connections if not flared properly or tightened to the correct torque may leak, which is the most common cause as to why an air conditioner needs to be re-gassed.

If a system has been installed for a long period of time (over 6 years) the copper piping used in the installation can develop tiny holes, cracks from vibration that can allow the refrigerant to leak and eventually lose all of the refrigerant. A service technician may just top up the system with gas, this is not the correct procedure if there is no gas in the air conditioner. Only if the system is close to the correct temperature/pressure a refrigerant adjustment maybe possible.  The correct way to re-gas an air conditioning system is that the refrigerant must be weighed inn,  in accordance to the air conditioner manufacture. This is displayed on the sticker on the outdoor condenser unit, this refrigerant maybe R22, R410A or R32 which are the most common refrigerants in air conditioning.

We carry a twelve month warranty on new installation for any refrigerant leaks, any second hand air conditioner does not carry a warranty. Other various issues may arise with air conditioners over a few years old, which may cause refrigerant leaks because of the vibration within in the system which is separate from the actual pipe connections from installation.

Air Conditioning Re-gas Breakdown/Leaking of refrigerant gas (unit is not cooling, common correct procedure for re-gas)

  • Recover any refrigerant or air in the system if required Air Conditioning Re-gas
  • Disconnect both ends of the interconnecting pipe work.
  • Cut off old flares and re-flare new.
  • Re-connect both ends using a lube behind the flares.
  • Tighten to correct torque.
  • Nitrogen charge unit pressure test if required.
  • Check for leaks.
  • Recover/vac down unit.
  • Re-gas unit (Weighed Inn using scales) and test run with the correct amount of refrigerant.

3 X Types of refrigerant most commonly used for air conditioning systems R22, R410A & R32:

Ducted Air Conditioning Re-gas: $145.00 incl. GST Call out Brisbane Metro Areas + $85 per hour for technicians labor. Refrigerant charged @ $30 per 100g for R22 refrigerant

Ducted Air Conditioning Re-gas: $145.00 incl. GST Call out Brisbane Metro Areas + $85 per hour for technicians labour. Refrigerant charged @ $15 per 100g for R410A refrigerant